Example

<< Click to Display Table of Contents >>

Navigation:  Super projects > Detailed feature descriptions > Symbol references between sub-projects >

Example

Previous pageReturn to chapter overviewNext page

This example is based on the same conditions that the previous example was. We therefore assume that we have a super project which is divided by location, with one sub-project for each location.

 

A contactor in location +S1 is documented in the sub-project for location +S1 with a coil main symbol and a contact mirror. The complete item designation is =A1+S1-K10.

 

A help contact to that contactor should be placed in another sub-project, a sub-project for location +S2.

 

Figure 1500: A contactor including one break help contact has been inserted in the first sub-project.

Figure 1500: A contactor including one break help contact has been inserted in the first sub-project.

 

Figure 1501: The item designation of the help contact may be typed manually, but it is also possible to select it, even if the main symbol is placed in another sub-project. Please use the ”Select” button shown in this figure.

Figure 1501: The item designation of the help contact may be typed manually, but it is also possible to select it, even if the main symbol is placed in another sub-project. Please use the ”Select” button shown in this figure.

 

Figure 1502:  The selection dialogue can present all item designation in the entire super project. You may however need to adjust the filter to include the designations that you currently are interested in.

Figure 1502:  The selection dialogue can present all item designation in the entire super project. You may however need to adjust the filter to include the designations that you currently are interested in.

 

Figure 1503:  You will get a default mirror booking directly (53,54 in this case), in the same way as within a conventional project.

Figure 1503:  You will get a default mirror booking directly (53,54 in this case), in the same way as within a conventional project.

 

Figure 1504:  The ”Select” button may be used to change which contact to book, in the same way as within a conventional project. The error message in the bottom may be ignored since the control is made within the sub-project only.

Figure 1504:  The ”Select” button may be used to change which contact to book, in the same way as within a conventional project. The error message in the bottom may be ignored since the control is made within the sub-project only.

 

Figure 1505:  An alternative contact is selected.

Figure 1505:  An alternative contact is selected.

 

Figure 1506:  Connection numbers are transferred from the contact mirror, and the cross-reference is updated immediately, in the same way as within a conventional project.

Figure 1506:  Connection numbers are transferred from the contact mirror, and the cross-reference is updated immediately, in the same way as within a conventional project.

 

Figure 1507:  A boundary box may be a clearer way of specifying a location that deviates from the rest of a drawing sheet.

Figure 1507:  A boundary box may be a clearer way of specifying a location that deviates from the rest of a drawing sheet.

 

Figure 1508:  The contact mirror in the other sub-project will be automatically updated with a correct cross-reference as soon as any sheet in the sub-project is opened.

Figure 1508:  The contact mirror in the other sub-project will be automatically updated with a correct cross-reference as soon as any sheet in the sub-project is opened.