Standard variables

<< Click to Display Table of Contents >>

Navigation:  Report Generator > Report variables > List of all report variables > Current variables > Swedish >

Standard variables

Previous pageReturn to chapter overviewNext page

Standard variables are used for several common concepts like item designations, attribute data and more. These concepts can be used in both device lists and connection lists, like wire lists, cable lists and terminal lists. Therefore, up to five variables are available for each concept, to be used in all those contexts.

 

*A.DBF is used for connection lists, both wire lists and cable lists, including cable core lists. A special variant of that is the *I.DBF which constitutes a bidirectional version of *A.DBF and which uses the same report variables.

 

*B.DBF is used for terminal lists. *X.DBF is an extended version intended for so-called “DIN cable and terminal plans”. It uses the same report variables but with several additions that are described further on.

 

Database XXXXXXXX below refers to report variables intended for devices in device lists and for terminals in terminal lists.

 

Database

Report variable

Field name

B

P1

P2

Description

B

!STATUS

STATUS


___


"K"=Terminal

"S"=Connector

A

!FBTYP

STATUS


___


Connection type according to specification for current wire/core:

1.Wire within a device

2.Wire between two devices

3.Wire between device and terminal

4.Wire between two terminals

5.Cable core (all cable cores except spares)

6.First cable core in each cable

7.All cable cores except spares and the first cable core of each cable

8.Spare cable cores defined by algorithm or cable mirror

XXXXXXXX

!BLKNR

QUELLNR


___


Special: internal handle within the sheet for symbol corresponding to current device

AB

!2BLKNR

QUELLNR


_V_


Special: Internal handle for symbol connected on the from/internal side

AB

!1BLKNR

QUELLNR


_N_


Special: Internal handle for symbol connected on the to/external side

AB

!2KBLKNR

QUELLNR


_1_


Special: Internal handle for cable to device on the from/internal side

B

!1KBLKNR

QUELLNR


_2_


Special: Internal handle for cable to device on the external side

AB

!ABLKNR

QUELLNR


_V_


Special: Internal handle for symbol connected on from/internal side

AB

!BBLKNR

QUELLNR


_N_


Special: Internal handle for symbol connected on to/external side

XXXXXXXX

!RITNING

DWGNAME


___


Internal drawing sheet code for symbol corresponding to current device

AB

!1RITNING

DWGNAME


_N_


Internal drawing sheet code for symbol connected on to/external

AB

!2KRITNING

DWGNAME


_1_


Internal drawing sheet code for cable to device on from/internal side

B

!1KRITNING

DWGNAME


_2_


Internal drawing sheet code for cable to device on external side

AB

!ARITNING

DWGNAME


_V_


Internal drawing sheet code for symbol connected on from/internal side

AB

!BRITNING

DWGNAME


_N_


Internal drawing sheet code for symbol connected on to/external side

XXXXXXXX

!BLKNIV

LEVEL


___


Special: Block level for symbol corresponding to current device

AB

!2BLKNIV

LEVEL


_V_


Special: Block level for symbol connected on from/internal side

AB

!1BLKNIV

LEVEL


_N_


Special: Block level for symbol connected on to/external side

AB

!2KBLKNIV

LEVEL


_1_


Special: Block level for cable to device on from/internal side

B

!1KBLKNIV

LEVEL


_2_


Special: Block level for cable to device on external side

XXXXXXXX

!BLKNAMN

BLKNAME


___


Symbol name for symbol corresponding to current device

AB

!2BLK

BLKNAME


_V_


Symbol name for symbol connected on from/internal side

AB

!1BLK

BLKNAME


_N_


Symbol name for symbol connected on to/external side

AB

!2KBLK

BLKNAME


_1_


Symbol name for cable to device on from/internal side

B

!1KBLK

BLKNAME


_2_


Symbol name for cable to device on external side

AB

!2X

X


_V_


X coordinate for symbol connected on from/internal side

AB

!1X

X


_N_


X coordinate for symbol connected on to/external side

AB

!2KX

X


_1_


X coordinate for cable to device on from/internal side

B

!1KX

X


_2_


X coordinate for cable to device on external side

AB

!2Y

Y


_V_


Y coordinate for symbol connected on from/internal side

AB

!1Y

Y


_N_


Y coordinate for symbol connected on to/external side

AB

!2KY

Y


_1_


Y coordinate for cable to device on from/internal side

B

!1KY

Y


_2_


Y coordinate for cable to device on external side

AB

!2LAYER

LAYER


_V_


Layer for symbol connected on from/internal side

AB

!2LAGER

LAYER


_V_


Layer for symbol connected on from/internal side

AB

!1LAYER

LAYER


_N_


Layer for symbol connected on to/external side

AB

!1LAGER

LAYER


_N_


Layer for symbol connected on to/external side

AB

!2KLAYER

LAYER


_1_


Layer for cable symbol to device on from/internal side

AB

!2KLAGER

LAYER


_1_


Layer for cable symbol to device on from/internal side

B

!1KLAYER

LAYER


_2_


Layer for cable symbol to device on external side

B

!1KLAGER

LAYER


_2_


Layer for cable symbol to device on external side

XXXXXXXX

!VINKEL

ORIENT


___


Rotation for symbol corresponding to current device

AB

!2VINKEL

ORIENT


_V_


Rotation for symbol connected on from/internal side

AB

!1VINKEL

ORIENT


_N_


Rotation for symbol connected on to/external side

AB

!2KVINKEL

ORIENT


_1_


Rotation for cable symbol to device on from/internal side

B

!1KVINKEL

ORIENT


_2_


Rotation for cable symbol to device on external side

XXXXXXXX

!XSKALA

XSCALE


___


X scale for symbol corresponding to current device

AB

!2XSKALA

XSCALE


_V_


X scale for symbol connected on from/internal side

AB

!1XSKALA

XSCALE


_N_


X scale for symbol connected on to/external side

AB

!2KXSKALA

XSCALE


_1_


X scale for cable symbol to device on from/internal side

B

!1KXSKALA

XSCALE


_2_


X scale for cable symbol to device on external side

XXXXXXXX

!YSKALA

YSCALE


___


Y scale for symbol corresponding to current device

AB

!2YSKALA

YSCALE


_V_


Y scale for symbol connected on from/internal side

AB

!1YSKALA

YSCALE


_N_


Y scale for symbol connected on to/external side

AB

!2KYSKALA

YSCALE


_1_


Y scale for cable symbol to device on from/internal side

B

!1KYSKALA

YSCALE


_2_


Y scale for cable symbol to device on external side

XXXXXXXX

!ANL

ANLAGE


___


Plant (function) for symbol corresponding to current device

AB

!2ANL

ANLAGE


_V_


Plant (function) for symbol connected on from/internal side

AB

!1ANL

ANLAGE


_N_


Plant (function) for symbol connected on to/external side

AB

!2KANL

ANLAGE


_1_


Plant (function) for cable symbol to device on from/internal side

B

!1KANL

ANLAGE


_2_


Plant (function) for cable symbol to device on external side

B

!HANL

ANLAGE


___


Plant (function) for current device

B

!PANL

ANLAGE


___


Plant (function) for current device

AB

!AANL

ANLAGE


_V_


Plant (function) for device connected on from/internal side

AB

!BANL

ANLAGE


_N_


Plant (function) for device connected on to/external side

XXXXXXXX

!PLAC

ORT


___


Location for symbol corresponding to current device

AB

!2PLAC

ORT


_V_


Location for symbol connected on from/internal side

AB

!1PLAC

ORT


_N_


Location for symbol connected on to/external side

AB

!2KPLAC

ORT


_1_


Location for cable symbol to device on from/internal side

B

!1KPLAC

ORT


_2_


Location for cable symbol to device on external side.

B

!HPLAC

ORT


___


Location for current device

B

!PPLAC

ORT


___


Location for current device

AB

!APLAC

ORT


_V_


Location for device connected on from/internal side

AB

!BPLAC

ORT


_N_


Location for device connected on to/external side

XXXXXXXX

!BLADNR

BLATT


___


Sheet number for symbol corresponding to current device

AB

!2BLADNR

BLATT


_V_


Sheet number for symbol connected on from/internal side

AB

!1BLADNR

BLATT


_N_


Sheet number for symbol connected on to/external side

A

!2KBLADNR

BLATT


_1_


Sheet number for cable to device on from-/internal side

B

!1KBLADNR

BLATT


_2_


Sheet number for cable to device on external side

B

!PBLNR

BLATT


___


Sheet number for symbol that represents the current terminal

XXXXXXXX

!HSYM

HBT


___


Obsolete

AB

!2HSYM

HBT


_V_


Obsolete

AB

!1HSYM

HBT


_N_


Obsolete

AB

!2KHSYM

HBT


_1_


Obsolete

B

!1KHSYM

HBT


_2_


Obsolete

XXXXXXXX

!IND

IND


___


Index for current device

AB

!2IND

IND


_V_


Index for device connected on from/internal side

AB

!1IND

IND


_N_


Index for device connected on to/external side

AB

!2KIND

IND


_1_


Index for cable to device on from-/internal side

B

!1KIND

IND


_2_


Index for cable to device on external side

B

!PIND

IND


___


Index for current terminal

XXXXXXXX

!NAMN

BEZ


___


Obsolete

AB

!2NAMN

BEZ


_V_


Obsolete

AB

!1NAMN

BEZ


_N_


Obsolete

AB

!2KNAMN

BEZ


_1_


Obsolete

B

!1KNAMN

BEZ


_2_


Obsolete

XXXXXXXX

!XREF

QVW


___


Cross-reference for symbol corresponding to current device

XXXXXXXX

!XREF<A>

QVW


E__

8

Cross-reference without plant (function)

XXXXXXXX

!XREF<P>

QVW


E__

16

Cross-reference without location

XXXXXXXX

!XREF<AP>

QVW


E__

24

Cross-reference without plant (function) and location

XXXXXXXX

!XREF<*A>

QVW


E__

9

Cross-reference with redundancy reduction for plant (function)

XXXXXXXX

!XREF<*P>

QVW


E__

17

Cross-reference with redundancy reduction for location

XXXXXXXX

!XREF<*AP>

QVW


E__

25

Cross-reference with redundancy reduction for plant (function) and location

AB

!2XREF

QVW


_V_


Cross-reference for symbol connected on from/internal side

AB

!2XREF<A>

QVW


EV_

8

Cross-reference without plant (function) for symbol on from/internal side

AB

!2XREF<P>

QVW


EV_

16

Cross-reference without location for symbol on from/internal side

AB

!2XREF<AP>

QVW


EV_

24

Cross-reference without plant (function) and location for symbol on from/internal side

AB

!2XREF<*A>

QVW


EV_

9

Cross-reference with redundancy reduction for plant (function) for symbol on from/internal side

AB

!2XREF<*P>

QVW


EV_

17

Cross-reference with redundancy reduction for location for symbol on from/internal side

AB

!2XREF<*AP>

QVW


EV_

25

Cross-reference with redundancy reduction for plant (function) and location for symbol on from/internal side

AB

!1XREF

QVW


_N_


Cross-reference for symbol connected on to/external side

AB

!1XREF<A>

QVW


EN_

8

Cross-reference without plant (function) for symbol on to/external side

AB

!1XREF<P>

QVW


EN_

16

Cross-reference without location for symbol on to/external side

AB

!1XREF<AP>

QVW


EN_

24

Cross-reference without plant (function) and location for symbol on to/external side

AB

!1XREF<*A>

QVW


EN_

9

Cross-reference with redundancy reduction for plant (function) for symbol on to/external side

AB

!1XREF<*P>

QVW


EN_

17

Cross-reference with redundancy reduction for location for symbol on to/external side

AB

!1XREF<*AP>

QVW


EN_

25

Cross-reference with redundancy reduction for plant (function) and location for symbol on to/internal side

AB

!2KXREF

QVW


_1_


Cross-reference for cable to device on from-/internal side

AB

!2KXREF<A>

QVW


E1_

8

Cross-reference without plant (function) for cable on from/internal side

AB

!2KXREF<P>

QVW


E1_

16

Cross-reference without location for cable on from/internal side

AB

!2KXREF<AP>

QVW


E1_

24

Cross-reference without plant (function) and location for cable on from/internal side

AB

!2KXREF<*A>

QVW


E1_

9

Cross-reference with redundancy reduction for plant (function) for cable on from/internal side

AB

!2KXREF<*P>

QVW


E1_

17

Cross-reference with redundancy reduction for location for cable on from/internal side

AB

!2KXREF<*AP>

QVW


E1_

25

Cross-reference with redundancy reduction for plant (function) and location for cable on from/internal side

B

!1KXREF

QVW


_2_


Cross-reference for cable to device on external side

B

!1KXREF<A>

QVW


E2_

8

Cross-reference without plant (function) for cable on external side

B

!1KXREF<P>

QVW


E2_

16

Cross-reference without location for cable on external side

B

!1KXREF<AP>

QVW


E2_

24

Cross-reference without plant (function) and location for cable on external side

B

!1KXREF<*A>

QVW


E2_

9

Cross-reference with redundancy reduction for plant (function) for cable on external side

B

!1KXREF<*P>

QVW


E2_

17

Cross-reference with redundancy reduction for location for cable on external side

B

!1KXREF<*AP>

QVW


E2_

25

Cross-reference with redundancy reduction for plant (function) and location for cable on external side

B

!PXREF

QVW


___


Cross-reference to symbol corresponding to current terminal

AB

!AXREF

QVW


_V_


Cross-reference to symbol connected on the from/internal side

AB

!BXREF

QVW


_N_


Cross-reference to symbol on the to/external side

XXXXXXXX

!XREFARB

QVW_ARB


___


Obsolete

AB

!2XREFARB

QVW_ARB


_V_


Obsolete

AB

!1XREFARB

QVW_ARB


_N_


Obsolete

AB

!2KXREFARB

QVW_ARB


_1_


Obsolete

B

!1KXREFARB

QVW_ARB


_2_


Obsolete

XXXXXXXX

!XREFDWG

QVW_DWG


___


Obsolete

AB

!2XREFDWG

QVW_DWG


_V_


Obsolete

AB

!1XREFDWG

QVW_DWG


_N_


Obsolete

AB

!2KXREFDWG

QVW_DWG


_1_


Obsolete

B

!1KXREFDWG

QVW_DWG


_2_


Obsolete

XXXXXXXX

!POSTART

NZ_SYM


___


Component type letter code for symbol corresponding to current device

AB

!2POSTART

NZ_SYM


_V_


Component type letter code for symbol connected on from/internal side

AB

!1POSTART

NZ_SYM


_N_


Component type letter code for device connected on to/external side

AB

!2KPOSTART

NZ_SYM


_1_


Component type letter code for cable to device on from/internal side

B

!1KPOSTART

NZ_SYM


_2_


Component type letter code for cable to device on external side

XXXXXXXX

!FUNKTION

ART


___


Function code (ART) for symbol corresponding to current device

AB

!2FUNKTION

ART


_V_


Function code (ART) for symbol connected on from/internal side

AB

!1FUNKTION

ART


_N_


Function code (ART) for symbol connected on to/external side

AB

!2KFUNKTION

ART


_1_


Function code (ART) for cable to device on from/internal side

B

!1KFUNKTION

ART


_2_


Function code (ART) for cable to device on external side

AB

!2ELD

ELD


_V_


Electrical data from attribute of symbol connected on from/internal side

AB

!1ELD

ELD


_N_


Electrical data from attribute of symbol connected on to/external side

AB

!2KDIM

ELD


_1_


Cable type from from attribute ELD of cable to device on from-/internal side

B

!1KDIM

ELD


_2_


Cable type from attribute ELD of cable to device on external side.

AB

!2D

ELD


_1_


Cable type from attribute ELD of cable to device on from-/internal side

B

!1D

ELD


_2_


Cable type from attribute ELD of cable to device on external side

XXXXXXXX

!POST

BKZ_ARB


___


Complete item designation of current device

XXXXXXXX

!POST<A>

BKZ_ARB


E__

2

Item designation of current device without plant (function)

XXXXXXXX

!POST<P>

BKZ_ARB


E__

4

Item designation of current device without location

XXXXXXXX

!POST<AP>

BKZ_ARB


E__

6

Item designation of current device without plant (function) and location

XXXXXXXX

!POST<*A>

BKZ_ARB


E__

3

Item designation with redundancy reduction for plant (function)

XXXXXXXX

!POST<*P>

BKZ_ARB


E__

5

Item designation with redundancy reduction for location

XXXXXXXX

!POST<*AP>

BKZ_ARB


E__

7

Item designation with redundancy reduction for plant (function) and location

XXXXXXXX

!POST<:NR>

BKZ_ARB


E__

32

Item designation without terminal/pin/socket number

XXXXXXXX

!POST<A:NR>

BKZ_ARB


E__

34

Item designation without plant (function) and terminal/pin/socket number

XXXXXXXX

!POST<P:NR>

BKZ_ARB


E__

36

Item designation without location and terminal/pin/socket number

XXXXXXXX

!POST<AP:NR>

BKZ_ARB


E__

38

Item designation without plant (function), location and terminal/pin/socket number

XXXXXXXX

!POST<*A:NR>

BKZ_ARB


E__

35

Item designation with redundancy reduction for plant (function), without terminal/pin/socket number

XXXXXXXX

!POST<*P:NR>

BKZ_ARB


E__

37

Item designation with redundancy reduction for location, without terminal/pin/socket number

XXXXXXXX

!POST<*AP:NR>

BKZ_ARB


E__

39

Item designation with redundancy reduction for plant (function) and location, without terminal/pin/socket number

XXXXXXXX

!POST<:UT>

BKZ_ARB


E__

64

Item designation without pin/socket number but with terminal number

XXXXXXXX

!POST<A:UT>

BKZ_ARB


E__

66

Item designation without plant (function) and pin/socket number but with terminal number

XXXXXXXX

!POST<O:UT>

BKZ_ARB


E__

68

Item designation without location and pin/socket number but with terminal number

XXXXXXXX

!POST<AO:UT>

BKZ_ARB


E__

70

Item designation without plant (function), location and pin/socket number but with terminal number

XXXXXXXX

!POST<*A:UT>

BKZ_ARB


E__

67

Item designation with redundancy reduction for plant (function), without pin/socket number but with terminal number

XXXXXXXX

!POST<*O:UT>

BKZ_ARB


E__

69

Item designation with redundancy reduction for location, without pin/socket number but with terminal number

XXXXXXXX

!POST<*AO:UT>

BKZ_ARB


E__

71

Item designation with redundancy reduction for plant (function) and location, without pin/socket number but with terminal number

XXXXXXXX

!POST>

BKZ_ARB

R

___


Right adjusted for FMT forms: Complete item designation of current device

XXXXXXXX

!POST<A>>

BKZ_ARB

R

E__

2

Right adjusted for FMT forms: Item designation of current device without plant (function)

XXXXXXXX

!POST<P>>

BKZ_ARB

R

E__

4

Right adjusted for FMT forms: Item designation of current device without location

XXXXXXXX

!POST<AP>>

BKZ_ARB

R

E__

6

Right adjusted for FMT forms: Item designation of current device without plant (function) and location

XXXXXXXX

!POST<*A>>

BKZ_ARB

R

E__

3

Right adjusted for FMT forms: Item designation with redundancy reduction for plant (function)

XXXXXXXX

!POST<*P>>

BKZ_ARB

R

E__

5

Right adjusted for FMT forms: Item designation with redundancy reduction for location

XXXXXXXX

!POST<*AP>>

BKZ_ARB

R

E__

7

Right adjusted for FMT forms: Item designation with redundancy reduction for plant (function) and location

XXXXXXXX

!POST<:NR>>

BKZ_ARB

R

E__

32

Right adjusted for FMT forms: Item designation without terminal/pin/socket number

XXXXXXXX

!POST<A:NR>>

BKZ_ARB

R

E__

34

Right adjusted for FMT forms: Item designation without plant (function) and terminal/pin/socket number

XXXXXXXX

!POST<P:NR>>

BKZ_ARB

R

E__

36

Right adjusted for FMT forms: Item designation without location and terminal/pin/socket number

XXXXXXXX

!POST<AP:NR>>

BKZ_ARB

R

E__

38

Right adjusted for FMT forms: Item designation without plant (function), location and terminal/pin/socket number

XXXXXXXX

!POST<*A:NR>>

BKZ_ARB

R

E__

35

Right adjusted for FMT forms: Item designation with redundancy reduction for plant (function), without terminal/pin/socket number

XXXXXXXX

!POST<*P:NR>>

BKZ_ARB

R

E__

37

Right adjusted for FMT forms: Item designation with redundancy reduction for location, without terminal/pin/socket number

XXXXXXXX

!POST<*AP:NR>>

BKZ_ARB

R

E__

39

Right adjusted for FMT forms: Item designation with redundancy reduction for plant (function) and location, without terminal/pin/socket number

XXXXXXXX

!POST<:UT>>

BKZ_ARB

R

E__

64

Right adjusted for FMT forms: Item designation without pin/socket number but with terminal number

XXXXXXXX

!POST<A:UT>>

BKZ_ARB

R

E__

66

Right adjusted for FMT forms: Item designation without plant (function) and pin/socket number but with terminal number

XXXXXXXX

!POST<O:UT>>

BKZ_ARB

R

E__

68

Right adjusted for FMT forms: Item designation without location and pin/socket number but with terminal number

XXXXXXXX

!POST<AO:UT>>

BKZ_ARB

R

E__

70

Right adjusted for FMT forms: Item designation without plant (function), location and pin/socket number but with terminal number

XXXXXXXX

!POST<*A:UT>>

BKZ_ARB

R

E__

67

Right adjusted for FMT forms: Item designation with redundancy reduction for plant (function), without pin/socket number but with terminal number

XXXXXXXX

!POST<*O:UT>>

BKZ_ARB

R

E__

69

Right adjusted for FMT forms: Item designation with redundancy reduction for location, without pin/socket number but with terminal number

XXXXXXXX

!POST<*AO:UT>>

BKZ_ARB

R

E__

71

Right adjusted for FMT forms: Item designation with redundancy reduction for plant (function) and location, without pin/socket number but with terminal number

AB

!2POST

BKZ_ARB


_V_


Complete item designation for device connected on from/internal side

AB

!2POST<A>

BKZ_ARB


EV_

2

Item designation without function (plant) for device connected on from/internal side

AB

!2POST<P>

BKZ_ARB


EV_

4

Item designation without location for device connected on from/internal side

AB

!2POST<AP>

BKZ_ARB


EV_

6

Item designation without function (plant) and location for device connected on from/internal side

AB

!2POST<*A>

BKZ_ARB


EV_

3

Item designation with redundancy reduction for function (plant), for device connected on from/internal side

AB

!2POST<*P>

BKZ_ARB


EV_

5

Item designation with redundancy reduction for location, for device connected on from/internal side

AB

!2POST<*AP>

BKZ_ARB


EV_

7

Item designation with redundancy reduction for function (plant) and location, for device connected on from/internal side

AB

!2POST<:NR>

BKZ_ARB


EV_

32

Item designation without terminal/pin/socket number for device connected on from/internal side

AB

!2POST<A:NR>

BKZ_ARB


EV_

34

Item designation without function (plant) and terminal/pin/socket number for device connected on from/internal side

AB

!2POST<P:NR>

BKZ_ARB


EV_

36

Item designation without location and terminal/pin/socket number for device connected on from/internal side

AB

!2POST<AP:NR>

BKZ_ARB


EV_

38

Item designation without function (plant), location, and terminal/pin/socket number, for device connected on from/internal side

AB

!2POST<*A:NR>

BKZ_ARB


EV_

35

Item designation with redundancy reduction for function (plant), without terminal/pin/socket number, for device connected on from/internal side

AB

!2POST<*P:NR>

BKZ_ARB


EV_

37

Item designation with redundancy reduction for location, without terminal/pin/socket number, for device connected on from/internal side

AB

!2POST<*AP:NR>

BKZ_ARB


EV_

39

Item designation with redundancy reduction for function (plant) and location, without terminal/pin/socket number, for device connected on from/internal side

AB

!2POST>

BKZ_ARB

R

_V_


Right adjusted for FMT forms: Complete item designation for device connected on from/internal side

AB

!2POST<A>>

BKZ_ARB

R

EV_

2

Right adjusted for FMT forms: Item designation without function (plant) for device connected on from/internal side

AB

!2POST<P>>

BKZ_ARB

R

EV_

4

Right adjusted for FMT forms: Item designation without location for device connected on from/internal side

AB

!2POST<AP>>

BKZ_ARB

R

EV_

6

Right adjusted for FMT forms: Item designation without function (plant) and location for device connected on from/internal side

AB

!2POST<*A>>

BKZ_ARB

R

EV_

3

Right adjusted for FMT forms: Item designation with redundancy reduction for function (plant), for device connected on from/internal side

AB

!2POST<*P>>

BKZ_ARB

R

EV_

5

Right adjusted for FMT forms: Item designation with redundancy reduction for location, for device connected on from/internal side

AB

!2POST<*AP>>

BKZ_ARB

R

EV_

7

Right adjusted for FMT forms: Item designation with redundancy reduction for function (plant) and location, for device connected on from/internal side

AB

!2POST<:NR>>

BKZ_ARB

R

EV_

32

Right adjusted for FMT forms: Item designation without terminal/pin/socket number for device connected on from/internal side

AB

!2POST<A:NR>>

BKZ_ARB

R

EV_

34

Right adjusted for FMT forms: Item designation without function (plant) and terminal/pin/socket number for device connected on from/internal side

AB

!2POST<P:NR>>

BKZ_ARB

R

EV_

36

Right adjusted for FMT forms: Item designation without location and terminal/pin/socket number for device connected on from/internal side

AB

!2POST<AP:NR>>

BKZ_ARB

R

EV_

38

Right adjusted for FMT forms: Item designation without function (plant), location, and terminal/pin/socket number, for device connected on from/internal side

AB

!2POST<*A:NR>>

BKZ_ARB

R

EV_

35

Right adjusted for FMT forms: Item designation with redundancy reduction for function (plant), without terminal/pin/socket number, for device connected on from/internal side

AB

!2POST<*P:NR>>

BKZ_ARB

R

EV_

37

Right adjusted for FMT forms: Item designation with redundancy reduction for location, without terminal/pin/socket number, for device connected on from/internal side

AB

!2POST<*AP:NR>>

BKZ_ARB

R

EV_

39

Right adjusted for FMT forms: Item designation with redundancy reduction for function (plant) and location, without terminal/pin/socket number, for device connected on from/internal side

AB

!1POST

BKZ_ARB


_N_


Complete item designation for device connected on to/external side

AB

!1POST<A>

BKZ_ARB


EN_

2

Item designation without function (plant) for device connected on to/external side

AB

!1POST<P>

BKZ_ARB


EN_

4

Item designation without location for device connected on to/external side

AB

!1POST<AP>

BKZ_ARB


EN_

6

Item designation without function (plant) and location for device connected on to/external side

AB

!1POST<*A>

BKZ_ARB


EN_

3

Item designation with redundancy reduction for function (plant), for device connected on to/external side

AB

!1POST<*P>

BKZ_ARB


EN_

5

Item designation with redundancy reduction for location, for device connected on to/external side

AB

!1POST<*AP>

BKZ_ARB


EN_

7

Item designation with redundancy reduction for function (plant) and location, for device connected on to/external side

AB

!1POST<:NR>

BKZ_ARB


EN_

32

Item designation without terminal/pin/socket number for device connected on to/external side

AB

!1POST<A:NR>

BKZ_ARB


EN_

34

Item designation without function (plant) and terminal/pin/socket number for device connected on to/external side

AB

!1POST<P:NR>

BKZ_ARB


EN_

36

Item designation without location and terminal/pin/socket number for device connected on to/external side

AB

!1POST<AP:NR>

BKZ_ARB


EN_

38

Item designation without function (plant), location, and terminal/pin/socket number, for device connected on to/external side

AB

!1POST<*A:NR>

BKZ_ARB


EN_

35

Item designation with redundancy reduction for function (plant), without terminal/pin/socket number, for device connected on to/external side

AB

!1POST<*P:NR>

BKZ_ARB


EN_

37

Item designation with redundancy reduction for location, without terminal/pin/socket number, for device connected on to/external side

AB

!1POST<*AP:NR>

BKZ_ARB


EN_

39

Item designation with redundancy reduction for function (plant) and location, without terminal/pin/socket number, for device connected on to/external side

AB

!1POST>

BKZ_ARB

R

_N_


Right adjusted for FMT forms: Complete item designation for device connected on to/external side

AB

!1POST<A>>

BKZ_ARB

R

EN_

2

Right adjusted for FMT forms: Item designation without function (plant) for device connected on to/external side

AB

!1POST<P>>

BKZ_ARB

R

EN_

4

Right adjusted for FMT forms: Item designation without location for device connected on to/external side

AB

!1POST<AP>>

BKZ_ARB

R

EN_

6

Right adjusted for FMT forms: Item designation without function (plant) and location for device connected on to/external side

AB

!1POST<*A>>

BKZ_ARB

R

EN_

3

Right adjusted for FMT forms: Item designation with redundancy reduction for function (plant), for device connected on to/external side

AB

!1POST<*P>>

BKZ_ARB

R

EN_

5

Right adjusted for FMT forms: Item designation with redundancy reduction for location, for device connected on to/external side

AB

!1POST<*AP>>

BKZ_ARB

R

EN_

7

Right adjusted for FMT forms: Item designation with redundancy reduction for function (plant) and location, for device connected on to/external side

AB

!1POST<:NR>>

BKZ_ARB

R

EN_

32

Right adjusted for FMT forms: Item designation without terminal/pin/socket number for device connected on to/external side

AB

!1POST<A:NR>>

BKZ_ARB

R

EN_

34

Right adjusted for FMT forms: Item designation without function (plant) and terminal/pin/socket number for device connected on to/external side

AB

!1POST<P:NR>>

BKZ_ARB

R

EN_

36

Right adjusted for FMT forms: Item designation without location and terminal/pin/socket number for device connected on to/external side

AB

!1POST<AP:NR>>

BKZ_ARB

R

EN_

38

Right adjusted for FMT forms: Item designation without function (plant), location, and terminal/pin/socket number, for device connected on to/external side

AB

!1POST<*A:NR>>

BKZ_ARB

R

EN_

35

Right adjusted for FMT forms: Item designation with redundancy reduction for function (plant), without terminal/pin/socket number, for device connected on to/external side

AB

!1POST<*P:NR>>

BKZ_ARB

R

EN_

37

Right adjusted for FMT forms: Item designation with redundancy reduction for location, without terminal/pin/socket number, for device connected on to/external side

AB

!1POST<*AP:NR>>

BKZ_ARB

R

EN_

39

Right adjusted for FMT forms: Item designation with redundancy reduction for function (plant) and location, without terminal/pin/socket number, for device connected on to/external side

AB

!2KAB

BKZ_ARB


_1_


Complete item designation for cable in cable list and internal side in terminal list

AB

!2KAB<A>

BKZ_ARB


E1_

2

Cable item designation without function (plant) for cable in cable list and internal side in terminal list

AB

!2KAB<P>

BKZ_ARB


E1_

4

Cable item designation without location for cable in cable list and internal side in terminal list

AB

!2KAB<AP>

BKZ_ARB


E1_

6

Cable item designation without function (plant) and location for cable in cable list and internal side in terminal list

AB

!2KAB<*A>

BKZ_ARB


E1_

3

Cable item designation with redundancy reduction for function (plant), for cable in cable list and internal side in terminal list

AB

!2KAB<*P>

BKZ_ARB


E1_

5

Cable item designation with redundancy reduction for location, for cable in cable list and internal side in terminal list

AB

!2KAB<*AP>

BKZ_ARB


E1_

7

Cable item designation with redundancy reduction for function (plant) and location, for cable in cable list and internal side in terminal list

AB

!2KAB>

BKZ_ARB

R

_1_


Right adjusted for FMT forms: Cable item designation for cable in cable list and internal side in terminal list

AB

!2KAB<A>>

BKZ_ARB

R

E1_

2

Right adjusted for FMT forms: Cable item designation without function (plant) for cable in cable list and internal side in terminal list

AB

!2KAB<P>>

BKZ_ARB

R

E1_

4

Right adjusted for FMT forms: Cable item designation without location for cable in cable list and internal side in terminal list

AB

!2KAB<AP>>

BKZ_ARB

R

E1_

6

Right adjusted for FMT forms: Cable item designation without function (plant) and location for cable in cable list and internal side in terminal list

AB

!2KAB<*A>>

BKZ_ARB

R

E1_

3

Right adjusted for FMT forms: Cable item designation with redundancy reduction for function (plant), for cable in cable list and internal side in terminal list

AB

!2KAB<*P>>

BKZ_ARB

R

E1_

5

Right adjusted for FMT forms: Cable item designation with redundancy reduction for location, for cable in cable list and internal side in terminal list

AB

!2KAB<*AP>>

BKZ_ARB

R

E1_

7

Right adjusted for FMT forms: Cable item designation with redundancy reduction for function (plant) and location, for cable in cable list and internal side in terminal list

B

!1KAB

BKZ_ARB


_2_


Complete item designation for cable on external side in terminal list

B

!1KAB<A>

BKZ_ARB


E2_

2

Cable item designation without function (plant) for cable on external side in terminal list

B

!1KAB<P>

BKZ_ARB


E2_

4

Cable item designation without location for cable on external side in terminal list

B

!1KAB<AP>

BKZ_ARB


E2_

6

Cable item designation without function (plant) and location for cable on  external side in terminal list

B

!1KAB<*A>

BKZ_ARB


E2_

3

Cable item designation with redundancy reduction for function (plant), for cable on external side in terminal list

B

!1KAB<*P>

BKZ_ARB


E2_

5

Cable item designation with redundancy reduction for location, for cable on external side in terminal list

B

!1KAB<*AP>

BKZ_ARB


E2_

7

Cable item designation with redundancy reduction for function (plant) and location, for cable on external side in terminal list

B

!1KAB>

BKZ_ARB

R

_2_


Right adjusted for FMT forms: Cable item designation for cable on external side in terminal list

B

!1KAB<A>>

BKZ_ARB

R

E2_

2

Right adjusted for FMT forms: Cable item designation without function (plant) for cable on external side in terminal list

B

!1KAB<P>>

BKZ_ARB

R

E2_

4

Right adjusted for FMT forms: Cable item designation without location for cable on external side in terminal list

B

!1KAB<AP>>

BKZ_ARB

R

E2_

6

Right adjusted for FMT forms: Cable item designation without function (plant) and location for cable on external side in terminal list

B

!1KAB<*A>>

BKZ_ARB

R

E2_

3

Right adjusted for FMT forms: Cable item designation with redundancy reduction for function, for cable on external side in terminal list

B

!1KAB<*P>>

BKZ_ARB

R

E2_

5

Right adjusted for FMT forms: Cable item designation with redundancy reduction for location, for cable on external side in terminal list

B

!1KAB<*AP>>

BKZ_ARB

R

E2_

7

Right adjusted for FMT forms: Cable item designation with redundancy reduction for function (plant) and location on external side in terminal list

AB

!BPOST

BKZ_ARB


_N_


Complete item designation for device on to/ external side

AB

!APOST

BKZ_ARB


_V_


Complete item designation for device on from/internal side

AB

!2K

BKZ_ARB


_1_


Cable item designation for cable in cable list or cable on internal side in terminal list

B

!1K

BKZ_ARB


_2_


Cable item designation for cable on external side in terminal list

XXXXXXXX

!EB_STAT

VA_STATUS


___


Obsolete

AB

!2EB_STAT

VA_STATUS


_V_


Obsolete

AB

!1EB_STAT

VA_STATUS


_N_


Obsolete

AB

!2KEB_STAT

VA_STATUS


_1_


Obsolete

B

!1KEB_STAT

VA_STATUS


_2_


Obsolete

XXXXXXXX

!KOLUMN

STROMPFAD


___


Column (part of cross-reference) for symbol corresponding to current device

AB

!2KOLUMN

STROMPFAD


_V_


Column (part of cross-reference) for symbol connected on from/internal side

AB

!1KOLUMN

STROMPFAD


_N_


Column (part of cross-reference) for symbol connected on to/external side

AB

!2KKOLUMN

STROMPFAD


_1_


Column (part of cross-reference) for cable in cable list and internal side in terminal list

B

!1KKOLUMN

STROMPFAD


_2_


Column (part of cross-reference) for cable symbol on external side in terminal list

XXXXXXXX

!RAD

ZEILE


___


Row (part of cross-reference) for symbol corresponding to current device

AB

!2RAD

ZEILE


_V_


Row (part of cross-reference) for symbol connected on from/internal side

AB

!1RAD

ZEILE


_N_


Row (part of cross-reference) for symbol connected on to/external side

AB

!2KRAD

ZEILE


_1_


Row (part of cross-reference) for cable in cable list and internal side in terminal list

B

!1KRAD

ZEILE


_2_


Row (part of cross-reference) for cable on external side in terminal list

XXXXXXXX

!RAKNARE

ZAEHLNUM


___


Counting number in item designation for current device

AB

!2RAKNARE

ZAEHLNUM


_V_


Counting number in item designation for device connected on from/internal side

AB

!1RAKNARE

ZAEHLNUM


_N_


Counting number in item designation for device connected on to/external side

AB

!2KRAKNARE

ZAEHLNUM


_1_


Counting number in item designation for cable in cable list and internal side in terminal list

B

!1KRAKNARE

ZAEHLNUM


_2_


Counting number in item designation for cable on external side in terminal list

XXXXXXXX

!FUNK

FUNKTION


___


Function (from FUNKTION attribute) for current device. Do not confuse function/funktion with function/plant.

AB

!2FUNK

FUNKTION


_V_


Function (from FUNKTION attribute) for device connected on from/internal side. Do not confuse function/funktion with function/plant.

AB

!1FUNK

FUNKTION


_N_


Function (from FUNKTION attribute) for device connected on to/external side. Do not confuse function/funktion with function/plant.

AB

!2KFUNK

FUNKTION


_1_


Function (from FUNKTION attribute) for cable in cable list and internal side in terminal list. Do not confuse function/funktion with function/plant.

B

!1KFUNK

FUNKTION


_2_


Function (from FUNKTION attribute) for cable on external side in terminal list. Do not confuse function/funktion with function/plant.

XXXXXXXX

!MODUL

MODULANZ


___


Symbol module (always 1) for symbol corresponding to current device

AB

!2MODUL

MODULANZ


_V_


Symbol module (always 1) for symbol connected on from/internal side

AB

!1MODUL

MODULANZ


_N_


Symbol module (always 1) for symbol connected on to/external side

AB

!2KMODUL

MODULANZ


_1_


Symbol module (always 1) for cable in cable list and internal side in terminal list

B

!1KMODUL

MODULANZ


_2_


Symbol module (always 1) for cable on external side in terminal list

XXXXXXXX

!PUTYP

PLNTYPE


___


Terminal or connector (KLM=terminal, STK=connector)

AB

!2PUTYP

PLNTYPE


_V_


Terminal or connector for device on to/external side:

KLM=terminal

STK=connector

AB

!1PUTYP

PLNTYPE


_N_


Terminal or connector for device on from/internal side:

KLM=terminal

STK=connector

XXXXXXXX

!SORT_XY

SORT_XY


___


System: Sequence number in x/y for current device

AB

!2SORT_XY

SORT_XY


_V_


System: sequence number in x/y for device on from/internal side

AB

!1SORT_XY

SORT_XY


_N_


System: sequence number in x/y for device on to/external side

AB

!2KSORT_XY

SORT_XY


_1_


System: sequence number in x/y for cable on from/internal side

B

!1KSORT_XY

SORT_XY


_2_


System: sequence number in x/y for cable on external side in terminal list

XXXXXXXX

!SORT_YX

SORT_YX


___


System: sequence number in y/x for current device

AB

!2SORT_YX

SORT_YX


_V_


System: sequence number in y/x for device on from/internal side

AB

!1SORT_YX

SORT_YX


_N_


System: sequence number in y/x for device on to/external side

AB

!2KSORT_YX

SORT_YX


_1_


System: sequence number in y/x for cable on from/internal side

B

!1KSORT_YX

SORT_YX


_2_


System: sequence number in y/x for cable on external side

XXXXXXXX

!ANM

MARK


___


Remark for current device

AB

!2ANM

MARK


_V_


Remark for device connected on from/internal side

AB

!1ANM

MARK


_N_


Remark for device connected on to/external side

AB

!2KANM

MARK


_1_


Remark for cable core in cable list and internal side in terminal list

B

!1KANM

MARK


_2_


Remark for cable core on external side in terminal list

AB

!2A

MARK


_1_


Remark for cable core in cable list and internal side in terminal list

B

!1A

MARK


_2_


Remark for cable core on external side in terminal list

AB

!PANM

MARK


_V_


Remark for device connected on from/internal side

AB

!AANM

MARK


_V_


Remark for device connected on from/internal side

AB

!BANM

MARK


_N_


Remark for device connected on to/external side

B

!NYCKEL

QUELLDWG


___


Reference to *G.DBF for current device

AB

!2NYCKEL

QUELLDWG_V


___


Reference to *G.DBF for device connected on from/internal side

AB

!1NYCKEL

QUELLDWG_N


___


Reference to *G.DBF for device connected on to/external side

AB

!2KNYCKEL

QUELLDWG_1


___


Reference to *G.DBF for cable in cable list and internal side in terminal list

AB

!1KNYCKEL

QUELLDWG_2


___


Reference to *G.DBF for cable on external side in terminal list

A

!ANR

AP_NR

L

___


Obsolete

A

!UTYP

S_B


___


Obsolete

A

!TDIM

OUT_DIM


___


Dimension

A

!0NR

NULL_NR


___


Wire number

A

!20NR

V_NULL_NR


___


Wire number in on the from side (reference backwards in wire chain)

A

!10NR

N_NULL_NR


___


Wire number out on the to side (reference forward in wire chain)

AB

!2ANR

V_AP

L

___


Connection point number, from/internal side

AB

!2UTYP

V_S_B


___


Connector type, from/internal side:

Stift=pin

Buchse=socket

AB

!AUTYP

V_S_B


___


Connector type, from/internal side:

Stift=pin

Buchse=socket

AB

!1ANR

N_AP

L

___


Connection point number, to/external side

AB

!1UTYP

N_S_B


___


Connector type, to/external side:

Stift=pin

Buchse=socket

AB

!BUTYP

N_S_B


___


Connector type, to/external side:

Stift=pin

Buchse=socket

A

!KPART

ADER_NR


___


Cable core number

A

!P

ADER_NR


___


Cable core number

A

!KLEN

KA_LANGE


___


Cable length

A

!KSTATUS

KAB_STATUS


___


Cable core:

" "=No

"!"=Spare

"1"=Unambiguously drawn

"2"=Ambiguously drawn

AB

!NOD

POT


___


Node name

A

!FBNR

DR_FOLGE


___


Wiring order or potential name where such is present in current node

A

!SIGNAL

SIGNAL


___


Signal name

B

!PPOST

KUS_NAME


___


Terminal group name

B

!PUTTAG

KUS_NUMMER

L

___


Terminal number

B

!2KPART

ADER_NR_V

L

___


Cable core number for cable on internal side

B

!1KPART

ADER_NR_N

L

___


Cable core number for cable on external side

B

!2KLEN

KA_LANGE_V


___


Length of cable on internal side

B

!1KLEN

KA_LANGE_N


___


Length of cable on external side

B

!2P

ADER_NR_V

L

___


Cable core number for cable on internal side

B

!1P

ADER_NR_N

L

___


Cable core number for cable on external side

B

!2L

KA_LANGE_V


___


Length of cable on internal side

B

!1L

KA_LANGE_N


___


Length of cable on external side

B

!1TDIM

N_OUT_DIM


___


Cable type (electrical data) for cable on external side

B

!2TDIM

V_OUT_DIM


___


Cable type (electrical data) for cable on internal side

B

!ALGOSORT

ALGOSORT


___


Sequence order according to numbering algorithm when applicable

B

!ALGOSTAT

ALGOSTAT


___


Terminal status:

"0"=Does not match algorithm

"1"=Matches algorithm

"2"=Spare (not drawn

B

!2BY

V_BUEGELN


___


Long links on internal side (ASCII semi graphics)

B

!1BY

N_BUEGELN


___


Long links on external side (ASCII semi graphics)

B

!4BY

V_BUEGELN2


___


Mirrored long links on internal side (used when external side is shown to the left in the terminal list)

B

!3BY

N_BUEGELN2


___


Mirrored long links on external side (used when external side is shown to the left in the terminal list)

B

!POSTNR

DATENSATZ


___


Record number (1 or 2 when terminal is represented by 2 records, additional records added when needed)

B

!TSORT

TSORT


___


Table sort according to project parameters for wire list sorting