<< Click to Display Table of Contents >> The old Report Generator (before cadett ELSA 5.0) |
These variables come from the old MS-DOS based Report Generator that was used in MG-CAD 4.2 and earlier, and in cadett ELSA older than version 5.0. In the very old days – before the arrival of Microsoft Windows – the Report Generator was sending control codes to the printer to control paper sizes and other settings.
Database |
Report variable |
Field name |
B |
P1 |
P2 |
Description |
---|---|---|---|---|---|---|
!P1 |
PROJVAR1 |
___ |
Reset (control code used by old report generator) |
|||
!P2 |
PROJVAR2 |
___ |
10 characters per inch (control code used by old report generator) |
|||
!P3 |
PROJVAR3 |
___ |
17 characters per inch (control code used by old report generator) |
|||
!P4 |
PROJVAR4 |
___ |
6 lines per inch (control code used by old report generator) |
|||
!P5 |
PROJVAR5 |
___ |
8 lines per inch (control code used by old report generator) |
|||
!P6 |
PROJVAR6 |
___ |
12 characters per inch (control code used by old report generator) |
|||
!P7 |
PROJVAR7 |
___ |
Landscape (control code used by old report generator) |
|||
!P8 |
PROJVAR8 |
___ |
Portrait (control code used by old report generator) |
|||
!P9 |
PROJVAR9 |
___ |
Top Of Form (control code used by old report generator) |
|||
!RES1 |
PROJVAR10 |
___ |
Form Feed (control code used by old report generator) |
|||
!RES2 |
PROJVAR11 |
___ |
Form Feed Reset (control code used by old report generator) |
|||
!RES3 |
PROJVAR12 |
___ |
Carriage Return (control code used by old report generator) |
|||
!RES4 |
PROJVAR13 |
___ |
Character Set PC8 (ASCII åäö with semi graphics) (control code used by old report generator) |
|||
!RES5 |
PROJVAR14 |
___ |
User defined (control code used by old report generator) |
|||
!RES6 |
PROJVAR15 |
___ |
User defined (control code used by old report generator) |
|||
!RES7 |
PROJVAR16 |
___ |
User defined (control code used by old report generator) |
|||
!RES8 |
PROJVAR17 |
___ |
User defined (control code used by old report generator) |
|||
!RES9 |
PROJVAR18 |
___ |
User defined (control code used by old report generator) |
|||
!STD_A |
ANLAGE |
___ |
Plant, identical with !ANL, not used in 4.15 and later (only used by older report generators) |
|||
!STD_O |
ORT |
___ |
Location, identical with !PLAC, not used in 4.15 and later (only used by older report generators) |
|||
!STD_B |
BLATT |
___ |
Sheet number for symbol corresponding to first device on the current report sheet |
|||
!STD_D |
DWGNAME |
___ |
Drawing sheet file name where the first device on the current report sheet is placed |
|||
!STD_I |
IND |
___ |
Multi index (index from the circuit diagram) for the first device on the current report sheet |
|||
!STD_K |
KUS_NAME |
___ |
Terminal group name |
|||
!PN |
SYSCNTa |
___ |
Serial number counter number 0 |
|||
!CNT1 |
SYSCNTb |
___ |
Serial number counter number 1 |
|||
!CNT2 |
SYSCNTc |
___ |
Serial number counter number 2 |
|||
!CNT3 |
SYSCNTd |
___ |
Serial number counter number 3 |
|||
!CNT4 |
SYSCNTe |
___ |
Serial number counter number 4 |
|||
!CNT5 |
SYSCNTf |
___ |
Serial number counter number 5 |
|||
!CNT6 |
SYSCNTg |
___ |
Serial number counter number 6 |
|||
!CNT7 |
SYSCNTh |
___ |
Serial number counter number 7 |
|||
!CNT8 |
SYSCNTi |
___ |
Serial number counter number 8 |
|||
!CNT9 |
SYSCNTj |
___ |
Serial number counter number 9 |
|||
!CNT10 |
SYSCNTk |
___ |
Serial number counter number 10 |
|||
!CNT11 |
SYSCNTl |
___ |
Serial number counter number 11 |
|||
!CNT12 |
SYSCNTm |
___ |
Serial number counter number 12 |
|||
!CNT13 |
SYSCNTn |
___ |
Serial number counter number 13 |
|||
!CNT14 |
SYSCNTo |
___ |
Serial number counter number 14 |
|||
!CNT15 |
SYSCNTp |
___ |
Serial number counter number 15 |
|||
!CNT16 |
SYSCNTq |
___ |
Serial number counter number 16 |
|||
!CNT17 |
SYSCNTr |
___ |
Serial number counter number 17 |
|||
!CNT18 |
SYSCNTs |
___ |
Serial number counter number 18 |
|||
!CNT19 |
SYSCNTt |
___ |
Serial number counter number 19 |
|||
!CNT20 |
SYSCNTu |
___ |
Serial number counter number 20 |